SmartPro LCD 120V 1300VA 720W Line-Interactive UPS, AVR, Tower, LCD, USB, 8 Outl

SmartPro LCD 120V 1300VA 720W Line-Interactive UPS, AVR, Tower, LCD, USB, 8 Outl

$179.99Price
  • Supports a basic desktop PC up to 64 min. during power outage
  • Features 8 protected outlets—4 battery-protected, 4 surge-only
  • Offers automatic voltage regulation (AVR)
  • LCD screen reports real-time UPS and power status
  • Plugs into any NEMA 5-15R socket
  • 3-year limited warranty
  • $250,000 Ultimate Lifetime Insurance 

UPC Code

037332174116

UPS Type

Line-Interactive

Rated input current (Maximum Load)

10.8A

Nominal Input Voltage(s) Supported

120V AC

UPS Input Connection Type        

5-15P

Input Circuit Breakers   

20A

UPS Input Cord Length (ft.)

6

Recommended Electrical Service

15A 120V

Input Phase       

Single-Phase

Output Volt Amp Capacity (VA)

1300

Output Capacity (kVA)  

1.3

Output Watt Capacity (Watts)

720

Nominal Voltage Details

120v nominal output in battery mode

Frequency Compatibility

60 Hz

Output Voltage Regulation (Line Mode)

120V (+9% / -12%)

Output Voltage Regulation (Battery Mode)

120V (±10%)

UPS Output Receptacles (Surge Suppression Only)

4 UPS outlets, 4 surge-only outlets

Output AC Waveform (AC Mode)             

Sine wave

Output AC Waveform (Battery Mode)   

PWM sine wave

Nominal Output Voltage(s) Supported   

110V; 115V; 120V

Output Receptacles       

(8) 5-15R

Individually Controllable Load Banks

No

Battery Type     

Valve Regulated Lead Acid (VRLA)

Half Load Runtime (min.)

10 minutes (360 watts)

Expandable Runtime     

No

DC System Voltage (VDC)

24

Battery Recharge Rate (Included Batteries)

Less than 6.3 hours from 10% to 90%

Internal UPS Replacement Battery Cartridge

RBC51  (requires 2)

Voltage Regulation Description 

Automatic voltage regulation (AVR) maintains line power operation with an input voltage range of 92 to 150

Overvoltage Correction                

Input voltages between 129 and 150 are reduced by 15%

Undervoltage Correction             

Input voltages between 92 and 108 are boosted by 18%

 

 

Front Panel LCD Display

LCD screen with scroll buttons indicates Input voltage, Output voltage, Frequency (Hz), AVR boost / cut status, Output load in watts, Output load percentage, Battery voltage and Estimated runtime in minutes

Switches             

Power switch offers whole UPS power control; Scroll/mute button enables LCD selection options and silences audible alarm; Test button initiates self test

Alarm Cancel Operation

Power-fail alarm can be silenced using alarm-cancel switch

Audible Alarm   

Audible alarm indicates power-failure and low-battery conditions

 

 

UPS AC Suppression Joule Rating

650

UPS AC Suppression Response Time

Instantaneous

UPS Dataline Suppression           

1 line TEL/DSL (1 in / 1 out); 10/100Base T Ethernet; Coax jacks (1 set)

EMI / RFI AC Noise Suppression 

Yes

 

 

Primary Form Factor       Tower

 

Cooling Method              

Fan

Installation Form Factors Supported with Included Accessories

Tower

Primary UPS Depth (mm)             

396

Primary UPS Height (mm)            

203

Primary UPS Width (mm)             

146

Shipping Dimensions (hwd / in.)

11.30 x 9.10 x 19.40

Shipping Weight (lbs.)   

24.70

UPS Power Module Dimensions (hwd, in.)

8 x 5.75 x 15.6

UPS Power Module Weight (kg)

9.39

UPS Power Module Weight (lbs.)

20.7

ENVIRONMENTAL

 

Operating Temperature Range

+32 to +104 degrees Fahrenheit / 0 to +40 degrees Celsius

Storage Temperature Range      

+5 to +122 degrees Fahrenheit / -15 to +50 degrees Celsius

Relative Humidity            

5 to 95%, non-condensing

AC Mode BTU / Hr. (Full Load)

100

Battery Mode BTU / Hr. (Full Load)

776

AC Mode Efficiency Rating (100% Load)

95%

Audible Noise   

Less than 36 dB, front side 1m

COMMUNICATIONS

 

Network Monitoring Port Description

Supports detailed monitoring of UPS and site power conditions

PowerAlert Software    

For local monitoring via the UPS’s built-in USB port, download PowerAlert Local software at https

//www.tripplite.com/poweralert

 

Communications Cable 

USB cabling included

WatchDog Compatibility

Supports Watchdog application, OS and hard-reboot restart options for remote applications

Network Management Card Description

Network management not supported

Communications Interface          

USB (HID enabled)

LINE / BATTERY TRANSFER

 

Transfer Time   

2 milliseconds (AC to battery mode), 6 milliseconds (battery to AC mode)

Low Voltage Transfer to Battery Power (Setpoint)

92

High Voltage Transfer to Battery Power (Setpoint)

150

FEATURES & SPECIFICATIONS

 

Cold Start (Startup in Battery Mode During a Power Failure)

Cold-start operation supported

High Availability UPS Features   

Automatic Voltage Regulation (AVR); Hot swappable batteries; Surge/noise protection

Green Energy-Saving Features  

Greater than 95% efficiency - GREEN UPS

STANDARDS & COMPLIANCE

 

UPS Certifications           

Tested to UL1778 (USA); Tested to CSA (Canada); Tested to NOM (Mexico); Meets FCC Part 15 Category

 A (EMI)

 

WARRANTY

 

Product Warranty Period (U.S. & Canada)

3-year limited warranty

Connected Equipment Insurance (U.S., Canada & Puerto Rico)

$250,000 Ultimate Lifetime Insurance